Series EA
The steam sterilizer range Series EA is recommended for use in surgical practices and clinics.
Offering a capacity of 1, 1.5 and 2 ISO Containers, they comply with both Euronorm EN 285 and Medical Device Directive in all points.
|
SPECIFIC CHARACTERISTICS
|
 |
 |
 |
 |
- 5 sterilization programs
- short program 134°C for sterilization of wrapped and unwrapped simple and complex instruments with shortened drying time
- standard program 134°C for sterilization of wrapped and unwrapped simple and complex instruments and porous materials
- standard program 121°C for sterilization of wrapped and unwrapped simple and complex instruments and porous materials
- container program 134°C for sterilization of wrapped massive or complex instruments and heavy loads in sterilization baskets or sterilization containers
- special program 134°C for sterilization of potentially prion-contaminated sterilization material with 18 minutes holding time acc. to RKI recommendation
- vacuum test program
- deaeration test program (Bowie & Dick Test)
- short cycle times via high-performance steam generator
- low-noise Aqua-Jet vacuum pump
- simple interaction via graphic display
- cycle protocol via built-in printer
- large-volume sterilization chamber contains up to 12 small containers (in the 2-ISO-chamber)
- chamber volume from 154 up to 300 Liters
|
 |
|
TECHNICAL DETAILS
- useable space 48 x 48 x 64 / 96 / 156 cm
- sterilization chamber made of CrNi-steel, material-no. 1.4404, electropolished
- double-walled chamber for pre-heating
- high-performance Aqua-Jet vacuum pump with water splitting acc. to DIN 1988 / DVGW
- fully automatic PLC-microprocessor control
- automatic process run monitoring with failure and warning messages
- measuring, control and regulation via absolute pressure transducer and PT100 resistance thermometer
- integrated high-performance steam generator (external steam connection is also possible)
- compact cabinet-design
- 1-door and 2-door design
- several options, also for laboratory application
|
TECHNICAL DATA |
Description
|
Dimensions
|
| useable space (h x w x d) |
48 x 48 x 64 / 96 / 129 cm |
| outer dimensions (h x w x d) |
184 x 90 x 91 / 123 / 156 cm (1-türige Version) |
| sterilization temperatures |
121°C / 134°C |
| capacity |
1, 1.5, 2 ISO-standard containers, 6, 8, 12 WEBECO-small containers resp. |
| net weight |
approx. 440 / 490 / 540 kg (1-door version) |
| connection ratings |
400 V; 50/60 Hz; 21 kW (3 kW for operation with external steam) |
| cold water connection |
G 1/2 |
| DS-water connection |
G 1/2 |
| floor drain |
DN50 with anti-syphon trap |
 |
DELIVERY |
Model
|
Description
|
Article-No.
|
| EA110 |
1 ISO / 1-door |
043581 |
| EA110-FD |
1 ISO / 1-door / external steam |
043582 |
| EA210 |
1 ISO / 2-door |
043583 |
| EA210-FD |
1 ISO / 2-door / external steam |
043584 |
| EA115 |
1.5 ISO / 1-door |
043585 |
| EA115-FD |
1.5 ISO / 1-door / external steam |
043586 |
| EA215 |
1.5 ISO / 2-door |
043587 |
| EA215-FD |
1.5 ISO / 2-door / external steam |
043588 |
| EA120 |
2 ISO / 1-door |
043589 |
| EA120-FD |
2 ISO / 1-door / external steam |
043590 |
| EA220 |
2 ISO / 2-door |
043591 |
| EA220-FD |
2 ISO / 2-door / external steam |
043592 |
 |
OPTIONS |
Upon request
|
|
|
 |
SPARE PARTS |
Model
|
Description
|
Article-No.
|
| door seal |
|
042483 |
| membrane filter |
for aeration |
030509 |
 |
CONSUMABLES |
Model
|
Description
|
Article-No.
|
| paper roll |
for printer |
043137 |
| test set |
test device (helix) with 100 chemo-indicator strips |
008934 |
| test set |
5 bio-indicators, incl. evaluation |
008935 |
 |
|
 |
 |
 |
|